DT Series – Deep Cycle flooded batteries. 

The DT series provides a reliable power source for your electric equipment. 

 

 

 

Additional Info

  • General Features:

    Proprietary grid alloy and paste formulation – maximizes capacity and life

    Enhanced Polypropylene containers – impact resistant for better durability

    Strong terminals – superior conductivity and high rate discharge performance

    Advanced TTP welding technology for a short and reliable current path with less electrical resistance – better performance

    Terminal protectors and removable handles – safe and convenient handling

  • Specifications (Click on the link to see PDF):
    Model Voltage
    (V)
    Performance Avarages
    after 15 Cycles
    Terminal
    Type  
    Maximum Overall
    DimensionsD

    mm (in.) 
    Approx.
    Weight
    Kg(lbs)
    Ampere Hour
    Capacity
    Minutes of
    DischargeC
    (Ah) (Min)
    20HRA 5HRB @25A @75A L W H TH
    DT606 6 210 175 380 105 WNT,LPT 260 (10 1/4) 180 (7 1/8) 248 (9 3/4) 279.5 (11 ) 25.5(56.2)
    DT106 6 225 185 445 115 WNT,LPT 260 (10 1/4) 180 (7 1/8) 248 (9 3/4) 279.5 (11 ) 27.0 (59.5)
    DT126 6 240 195 485 130 WNT,LPT 260 (10 1/4) 180 (7 1/8) 248 (9 3/4) 279.5 (11 ) 28.3 (62.4)
    DT146 6 260 215 530 145 WNT,LPT 260 (10 1/4) 180 (7 1/8) 248 (9 3/4) 279.5 (11 ) 29.0 (63.9)
    DT866 8 150 125 225 E WNT,LPT 260 (10 1/4) 180 (7 1/8) 248 (9 3/4) 279.5 (11 ) 25.0 (55.1)
    DT876 8 170 145 295 F WNT,LPT 260 (10 1/4) 180 (7 1/8) 248 (9 3/4) 279.5 (11 ) 27.6 (60.9)
    DT896 8 190 155 340 G WNT,LPT 260 (10 1/4) 180 (7 1/8) 248 (9 3/4) 279.5 (11 ) 29.3 (64.6)
    DT8240 8 240 190 415 110 WNT,LPT 260 (10 1/4) 180 (7 1/8) 285(10 1/8) 317 (12  1/2) 35.0 (77.2)
    DT1275 12 150 120 280 H WNT,LPT 328 (12 7/8) 180 (7 1/8) 248 (9 3/4) 279.5 (11 ) 35.0 (77.2)
    A 20 hour rate is a BCI sanctioned rating expressing ampere hours required to achieve an end voltage of 1.75V/cell
    at 27℃(80oF) and represents the batteries maximum capacity.
    B 5 hour rate is based on IEC ( International Electrotechnical Commission) temperature standard of 30℃( 86oF).
    C Reserve Capacity or Capacity - the number of minutes a battery can be discharged;at 25 or 75 amps
    ( 56 amps for 8 volt batteries ) at 27℃( 80oF)and maintain a voltage above 1.75V/cell .
    D All dimensions taken from bottom of battery to top of terminal heights may vary according to type of terminals specified.
    E Capacity @ 56 amps is 90 minutes.
    F Capacity @ 56 amps is 117 minutes.
    G Capacity @ 56 amps is 132 minutes.
    H Capacity @ 56 amps is 102 minutes.